Hobart FT900BD Dishwasher User Manual


 
18
Parameters Menu
The Parameters Menu Table 1 lists the parameter name, a short description, a list of possible values
the parameter can have, the factory default value based on the specific dishwasher model and the
security level required to access that parameter.
PARAMETERS MENU TABLE 1
Parameter Description Model Possible Default Security
Name Values Value Required
Conveyor Speed Adjusts the speed of the conveyor in feet per FT900 4 10 8.5 SO
minute. Increasing the value can increase the FT900D 4 8.5 8.5
throughput of ware, but can decrease the ability FT900S 4 6.3 6.3
to sufficiently clean difficult items, such as food FT900SD 4 6.3 6.3
particles cooked onto pots and pans.
Low FR Temp Enables or disables a visual alarm on the display that Enabled Disabled M
Alarm indicates that Final Rinse water temperature is below the or
NSF required minimum of 180°F (82°C). When enabled, a Disabled
message will display notifying the user of this condition.
However, machine operation will not change and ware will
continue to run through the machine as expected. When
disabled, there will be no extra message indicating a
low-temperture event; however, the temperature display will
still show the current Final Rinse water temperature.
SuperOp. Access Enables or disables the SuperOperator access level. Enabled Disabled M
When enabled, this allows any user to modify values in or
the Parameters Menu that are marked as requiring only Disabled
SO security without entering a password. This can be
useful, for example, to allow the operator to adjust conveyor
speed based on the volume of dishes entering the dish
room without the need for intervention by a manager.
When disabled, the only operation allowed by any user is
the ability to enter the Security Code and exit the menu.
No parameters are allowed to be modified.
Change Mgr. Code Sets a new Security Code for elevating access to the 0000
Manager Level. to 1001 M
It is recommended to change this from the default value 8888
and store the new code where all kitchen managers, but no
operators, can access it.
Edit Enters the Communications Setup submenu, where settings M
Communications for the NAFEM Data Protocol can be changed. Please refer
Setup? to Communications Setup Menu Table 2 for more details.
Save Settings Exits the Parameters menu and returns to the main screen. SO
and Exit? Any settings that were changed are saved and most
become active immediately.
(If one or more settings are not active immediately, a
message will display indicating that you need to cycle
power to make them active.)
Cancel Settings Exits the Parameters menu and returns to the main screen. SO
and Exit? Any settings that were changed are cancelled and revert
back to the previous saved values.