– 25 –
Measure Clearance
Pour enough fl our in the bowl to cover the bottom of the bowl where the beater travels. With the bowl fully
raised (beater should not touch the bottom of the bowl), briefl y run the mixer at the lowest speed.
Turn off the mixer, disconnect the electrical power supply, and measure the depth of fl our where the
beater has traced a path. This measurement should be taken at several points around the bowl to assure
accuracy.
Adjust the Bowl/Agitator Clearance
• Remove the apron (which is secured by
thumbscrews).
• Adjust the stop screw on left side.
- Loosen the bottom locking nut, (Fig. 13)
and turn the stop screw counterclockwise
to increase the clearance or clockwise to
decrease the clearance.
- Tighten the locking nut while holding the
stop screw.
• After the adjustments are made, replace the
apron and secure it with the thumbscrews.
• Reconnect the electrical power supply.
• Carefully operate the bowl lift several times
to check the adjustment.
Fig. 13