LOCATION
The HO300G and HO300E Mini Rotating Rack Ovens must have the following minimum clearances
to combustibles:
Back and sides: 0"
Bottom: 0"
Top: 18" (45.7 cm)
NOTE: Minimum 24" clearance needed for service access on the right side. If right side is within 30"
of radiant heat or grease vapor source, vent guard is required.
Be sure that electrical, water and drain connections are accessible and can be made per local and
national codes. The equipment area must be kept free and clear of combustible substances.
Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the
combustion chamber must be provided. Make sure there is an adequate supply of air in the room to
replace air taken out by the ventilating system.
INSTALLATION CODES AND STANDARDS
The oven must be installed in accordance with:
In the United States of America:
1. State and local codes.
2.
National Fuel Gas Code
, ANSI-Z223.1 (latest edition). Copies may be obtained from The
American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3.
National Electrical Code
, ANSI/NFPA-70 (latest edition).
In Canada:
1. Local codes.
2. CAN/CGA-B149.1
Natural Gas Installation Code
(latest edition).
3. CAN/CGA-B149.1
National Fuel Gas Code
(latest edition), available from The Canadian Gas
Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.
ASSEMBLY
The oven must be installed on a stand, proofer cabinet or any noncombustible surface.
The oven must be sealed to the stand, proofer cabinet or surface with an NSF-approved sealant, such
as Dow Corning 732 or GE RTV108.
Secure the oven to the proofer or stand using the provided tie-down brackets, which mount on the rear
of the oven. (See Accessories - HPC800 Proofing Cabinet for proofer specifications.)
Oven Mounted on a Stand or Proofer with Caster
For an appliance equipped with casters, instructions that (1) the installation shall be made with a
connector that complies with the Standard for
Connectors for Movable Gas Appliances, ANSI Z21.69
or
Connectors for Moveable Gas Appliances, CAN/CGA-6.1
6, and a quick-disconnect device that
complies with the Standard for
Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41
, or
Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9
, (2) adequate means must be provided
to limit the movement of the appliance.