Hobart LXiH ML-130017 Dishwasher User Manual


 
– 10 –
INSTALLATION DIAGRAM (LXiC & LXiH)
WARNING:
REQUIRED FLOWING WATER PRESSURE TO THE DISHMACHINE IS 20 ± 5 PSIG. IF
PRESSURES HIGHER THAN 25 PSIG ARE PRESENT, A PRESSURE REGULATING VALVE
MUST BE INSTALLED IN THE WATER LINE TO THE DISHMACHINE (BY OTHERS).
IMPORTANT: THE SODIUM HYPOCHLORITE (LIQUID BLEACH) CONTAINER SHOULD BE
PLACED NO HIGHER THAN 10" ABOVE FLOOR.
IF BLEACH CONTAINER IS TO BE PLACED IN CABINET ADJACENT TO MACHINE, A 1/2" DIA.
HOLE IS REQUIRED IN THE CABINET TO RUN BLEACH SUPPLY LINE.
USE ONLY 6% SODIUM HYPOCHLORITE (LIQUID BLEACH) AS SANITIZING CHEMICAL TO
INSURE PROPER OPERATION OF DISHMACHINE. IF 8.4% IS TO BE UTILIZED CONTACT
HOBART SERVICE TO CHANGE THE SANITIZER PUMP SETTINGS.
DO NOT PRE-MIX RINSE AGENT AND SODIUM HYPOCHLORITE (LIQUID BLEACH).
CERTAIN MATERIALS INCLUDING SILVER PLATE, ALUMINUM AND PEWTER ARE ATTACKED
BY SODIUM HYPOCHLORITE (LIQUID BLEACH). SEE INSTRUCTIONAL MANUAL.
STEAM GENERATED FROM NORMAL OPERATION MAY ESCAPE FROM THE DOOR. WOOD
LAMINATE, VENEERS, ETC. ARE UNSUITABLE MATERIALS FOR USE IN AREAS EXPOSED
TO DISHWASHER STEAM AND DETERGENTS. STAINLESS STEEL OR OTHER MOISTURE-
RESISTANT SHIELDS ARE RECOMMENDED FOR SURFACES ADJACENT TO LXi SIDES
AND TOP.
NOTES:
1. ALL VERTICAL MACHINE DIMENSIONS TAKEN FROM FLOOR MAY BE INCREASED BY 1".
2. MOIST AIR ESCAPES FROM THE DOOR.
USE ONLY MOISTURE RESISTANT MATERIALS ADJACENT TO LXi SIDES AND TOP.
3. A VENT HOOD IS NOT RECOMMENDED ABOVE THE LXi UNDERCOUNTER DISHWASHER
SINCE IT DOES NOT PRODUCE EXCESSIVE VAPORS
PLUMBING NOTES:
1. WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE
SUPPLIED (BY OTHERS) IN COMMON WATER SUPPLY LINE AT SERVICE CONNECTION.
2. RECOMMENDED WATER HARDNESS TO BE 4-6 GRAINS FOR BEST RESULTS.
3. MINIMUM WATER CONDUCTIVITY REQUIRED - 30 MICRO-MHOS/CM.
4. IF DRAIN HOSE IS LOOPED ABOVE A SINK, THE LOOP MUST NOT EXCEED 38" AFF.
* THIS SYSTEM REQUIRES THREE POWER WIRES WHICH INCLUDES
A CURRENT CARRYING NEUTRAL, AN ADDITIONAL FOURTH WIRE
MUST BE PROVIDED FOR MACHINE GROUND.
ACCESSORY CORD KITS AVAILABLE FOR ALL MACHINES
WARNING
ELECTRICAL AND GROUNDING CONNECTIONS
MUST COMPLY WITH THE APPLICABLE PORTIONS
OF THE NATIONAL ELECTRICAL CODE AND/OR
OTHER LOCAL ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH
APPLICABLE SANITARY, SAFETY AND PLUMBING
CODES. DRAIN AND FILL LINE CONFIGURATIONS
VARY, SOME METHODS ARE SHOWN ON THIS DRAWING.
SHIPPING WEIGHTS (LBS) LXiC LXiH
NET WEIGHT OF MACHINE 190 lbs. 210 lbs.
DOMESTIC SHIPPING WEIGHT 235 lbs. 255 lbs.
CONNECTION INFORMATION
(AFF = ABOVE FINISHED FLOOR)
LEGEND
E1 ELECTRICAL CONNECTION: 1-3/8" DIA. HOLE
FOR 1" TRADE SIZE CONDUIT; 31-3/4" AFF.
P1 SINGLE FILL AND RINSE CONNECTION:
3/4" FEMALE GARDEN HOSE FITTING ON 6' LONG
HOSE SUPPLIED WITH MACHINE; 140°F WATER
MIN. FOR LXiC, 110°F WATER MIN. FOR LXiH,
1-1/2" AFF.
P2 DRAIN CONNECTION: 3/4" MPT FITTING WITH
6' LONG HOSE SUPPLIED WITH MACHINE;
3-9/16" AFF.
MACHINE TYPE & RATED
MIN SUPPLY MAX
CKT CONDUCT PROTECTIVE
SPECIFICATION AMPS
AMPACITY DEVICES
LXiC (120/60/1)
USE 90°C STRANDED 15.4 20 20
COPPER WIRE ONLY.
LXiC (120/208-240(3W)/60/1*)
LXiC (208-240/60/1)
USE 90°C STRANDED 13.6 20 20
COPPER WIRE ONLY.
LXiH (120/208-240(3W)/60/1*)
LXiH (208-240/60/1)
USE 90°C STRANDED
COPPER WIRE ONLY. 37.7 50 50
ELECTRICAL OPTIONS BELOW ARE NON STANDARD VOLTAGES AVAILABLE
AT EXTRA COST. CONSULT FACTORY FOR PRICING AND LEAD TIME.
LXiH 208-240/60/3 29.5 35 35
480/60/3 14.8 20 20
220-240/50/1 38.1 50 50
380-400/60/3 17.1 25 25