DIAGNOSTIC MESSAGES
In the event of a problem with a temperature probe, the display will flash P1, P2 or P3 every second.
The respective heaters will shut down. Other functions will continue to operate normally. Contact your
local Hobart Service Office.
Drain and fill error messages are displayed as E0, E1, E2, E3, E4, E5, E6 or E7. In all cases, the
dishwasher will terminate current cycle operations, turn off all heat sources and display the message
until the OFF button is pressed. (A power drain will not occur when turned off.) (See Troubleshooting.)
If problem persists, contact your local Hobart Service Office.
If the control detects that the water level probe is becoming less sensitive, CL and Pr are displayed in
the control window. Clean all three water level probes. (See Cleaning.)
WASH/RINSE CYCLE TIMES (LXi)
Spritz 2 Sec.
Wash 85 Sec.**
Drain 22 Sec. Max.*
Dwell 1 Sec.
Rinse 10 Sec.
Dwell 5 Sec.
* Drains off about
3
/4 gallon of water.
** Maximum wash time may vary, depending on operation voltage and incoming water temperature
for 70°F rise.
WASH/RINSE CYCLE TIMES (LXiG)
Spritz 2 Sec.
Wash 45 Sec.**
Drain 22 Sec. Max.*
Dwell 1 Sec.
Rinse 10 Sec.
Dwell 5 Sec.
* Drains off about
3
/4 gallon of water.
** Maximum wash time may vary, depending on operation voltage and incoming water temperature
for 70°F rise.