Hobart P660 Mixer User Manual


 
– 11 –
TROUBLESHOOTING
SYMPTOMS POSSIBLE CAUSES
Mixer will not start. 1. Circuit protector in open position — check fuse or
disconnect switch.
2. Mixer or attachment overloaded.
3. Bowl not all the way up.
4. Wire Cage Assembly is not in the front-center
position.
Agitator touches bowl. 1. Bowl clamp(s) not closed.
2. Improper agitator clearance — see MAINTENANCE
for adjustment procedure.
3. Bowl clamp(s) improperly adjusted — see
MAINTENANCE for adjustment procedure.
Planetary seal squeaks. 1. Seal requires occasional lubrication — see
MAINTENANCE.
SERVICE
If service is needed on this equipment, contact your local Hobart service office.
Our Hobart trained service technicians strategically located at the many Hobart branches are prepared
to give you fast, efficient and reliable service. Protect your investment by having a Hobart inspection
contract which assures the continued, efficient operation of your Hobart machines, spares and
accessories.
For further details, contact your local regional office:
London & Home Counties 01234 841220
Scotland & N. Ireland 0141 7743456
Midland & Wales 0121 7898228
Southern 01454 616048
Northern 0113 2759727
The Hobart Manufacturing Company Limited
Hobart House
51 The Bourne Telephone: 0181 920 2800 Fax: 0181 886 0450
Southgate
London N14 6RT