Hobart V1401 Mixer User Manual


 
– 5 –
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
A junction box with threaded hole for
3
4" trade size conduit is located at the top of the pedestal. Make
electrical connections per the wiring diagram located on the inside of the Top Cover.
Check Rotation (Three-Phase Machines Only)
Three-phase machines must be connected so the planetary rotates in the direction of the arrow on the
Drip Cup. To check rotation:
Set the gear shift lever on 1.
Apply power to the mixer, set the Electro-Mechanical Timer on HOLD; or, if equipped with a
Programmable Timer Controller, set it on [ -- : -- ]. Place the Bowl Support all the way up. Set
the speed on 1. Position the clutch on RUN. Momentarily run the machine by pushing the START
and then STOP buttons.
If rotation is incorrect, DISCONNECT ELECTRICAL POWER SUPPLY and interchange any two
of the incoming power supply leads.