Installation Steps (continued)
TrueFRESH™ ERV/HRV Ventilation Systems 69-2480EF—05 17
6
Connecting the power cord
ERV/HRV Power Cord
Insert the power cord on top of the unit. Press firmly
to make sure the power cord is secure.
IMPORTANT: Do not plug the power cord into the
wall receptacle at this time.
Electric Wall Outlet
Honeywell recommends that the unit has a dedicated receptacle
with 120 VAC.
Avoid connecting the unit to the wall receptacle with an
extension cord.
Honeywell does not recommend the use of an extension cord.
Ensurethatthereceptacle’spolarizationiscorrect.
NOTE: IftheLEDlightontheERV/HRVcontrolpanelremainsgreen,themotorsdonotenergize,and
thecontrolsdonotoperate;thiscanindicatethatthepolarizationinthemainACoutletis
inverted.
IMPORTANT: Always consult a qualified technician to ensure proper installation of main power.
Installing outside hoods for the fresh air and the exhaust
7
Locate the outside hoods at least 18 inches
(0.46m)abovegradeandatleast72inches
(1.83 m) apart.
NOTE: Do not locate the fresh air vent
hood close to known sources of
pollutants such as dryer vents.
IMPORTANT: Always consult your
local code for spacing
requirements in your area.
72 (1,829)
18 (457)
M32372