H. Startup
WARNING
1. All parts are factory-adjusted. Improper adjustments may adversely affect
safety, performance, component life, and warranty coverage.
2. If the icemaker is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the compressor.
3. At startup, conrm that all internal and external connections are free of leaks.
1) Open the water supply line shut-off valve.
2)Makesurethecontrolswitchisinthe"OFF"position.Plugtheunitintotheelectrical
outlet. If you have to slide the unit back for a built-in installation, make sure you do not
damage or pinch the water supply, drain connections, or power cord.
3) If required by sanitation code in your area, seal the perimeter where the machine
touches the oor with approved caulk compound in a smooth and easily cleanable
manner.
4)Movethecontrolswitchtothe"ICE"positionandallowtheicemakertooperatefor
2 minutes. This allows the water tank to ll.
5)Movethecontrolswitchtothe"OFF"position.
6) Inside the storage bin, disconnect the suction tube by squeezing the tabs and pulling
the tube clear. See Fig. 31. Allow the water tank to drain.
7) Reconnect the suction tube as illustrated. See Fig. 32. Make sure the tabs lock into
place; a loose tting may cause a water leak.
8) Clean the storage bin liner, door liner, and door gasket using a neutral cleaner. Rinse
thoroughly after cleaning.
9)Movethecontrolswitchtothe"ICE"positiontostarttheautomaticicemakingprocess.
10) To conrm bin control operation, hold ice in contact with the bin control thermostat bulb.
The icemaker should stop within 10 seconds. Adjustment may be needed, particularly at
higher altitude locations.
Water Tank
Drain
Suction Tube
Tabs
Fig. 31 Fig. 32
Suction Tube
Tabs