Hoshizaki DCM-750BWH Ice Maker User Manual


 
40
Problem Possible Cause Remedy
[3]
Ice purge cycle will
not start.
a) Water Control Relay .Low water safety
circuit open
(bad contacts ).
.Replace.
b) Control Switch .Bad contacts. .Check for continuity and
replace.
c) Bin Control .Open. .Bin full, check for
continuity on proximity
switch.
d) Control Board .Fails to operate gear
motor relay.
.See "II.D.4. Control Board
Check Procedure."
e) Gear Motor Fuse .Blown. .Check gear motor
amperage, bearing
wear (see "V.F.. Upper
Bearing Wear Check"),
and supply voltage.
f) Gear Motor Thermal
Protector
.Open. .Check gear motor
bearings, supply voltage.
g) Gear Motor .Open windings. .Replace.
.
Auger coupling broke. .Replace.
3.Locked bearings. 3.Replace.
[4]
Freeze cycle will not
start (compressor).
a) Gear Motor Protect
Relay
.Open coil. .Replace.
.
Open contacts. . Replace.
b) Control Board .Defective. .See "II.D.4. Control Board
Check Procedure."
c) Starter (Start Relay) .Bad contacts. .Check for continuity and
replace.
.
Coil winding open. .Replace.
3.Loose connections. 3.Tighten.
d) Start Capacitor or Run
Capacitor
.Defective. .Replace.
e) Compressor .Power supply not
within specications.
.Refer to nameplate and
correct.
.
Wiring to compressor. .Check for loose or open
connection, repair or
replace.
3.Defective. 3.Replace.
4.Compressor locked
and internal motor
protector tripped.
4.Replace.
[5] All components
run, but no ice is
produced.
a) Refrigerant .Low charge. .See "V.B. Service for
Refrigerant Lines."
.
Refrigerant line or
component restricted.
.Remove the restriction or
component and replace
the drier.
3.Air or moisture
trapped.
3.Recover refrigerant,
replace drier, evacuate,
and recharge.
b) Expansion Valve .Bulb loose. .Secure bulb.
.
Operating erratically. .Check and replace.
c) Compressor .Defective. .Replace.