Hoshizaki DCM-750BWH Ice Maker User Manual


 
6
2. DCM-750BAH-OS
Note: We reserve the right to make changes in specications and design without prior
notice.
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 13.2 RLA 60 LRA
GEAR MOTOR 120 V 3 FLA 1/4 HP
FAN MOTOR 120 V 0.85 FLA 1/15 HP
AGITATING MOTOR 120 V 1.8 FLA (Total) 110 W
DISPENSING MOTOR 120 V 0.9 FLA 55 W
OTHER 120 V 0.6 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACIT
Y
20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 * 803 (364) 770 (349) 726 (329)
Reference without *marks 80 684 (310) 645 (293) 608 (276)
90 573 (260) * 567 (257) 509 (231)
100 480 (218) 452 (205) * 423 (192)
SHAPE OF ICE Cubelet (Compressed Flake Ice)
ICE QUALITY Approx. 90%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY 95 lbs.
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 1481 (6.3) 1449 (4.3)
POTABLE WATER 68 (12) 96 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 34-1/16" x 28-1/2" x 48-1/16" (865 x 723 x 1221 mm)
EXTERIOR FINISH Stainless Steel; Galvanized Steel (Rear)
WEIGHT Net 375 lbs. ( 170 kg ), Shipping 405 lbs. ( 184 kg )
CONNECTIONS - ELECTRIC Permanent Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Drain Pan 3/4" FPT
Bin Drain 3/4" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
DISPENSER CONTROL SYSTEM Photoelectric Sensor (Infrared)
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS55C2E-CAA-219
CONDENSER Air-cooled, Fin and tube type
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 1 lb. 7.1 oz. (660 g)
DESIGN PRESSURE High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch and Time
r
ACCESSORIES - SUPPLIED Spare Fuse
- REQUIRED Legs
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
ENG F-013.0.1196