Hoshizaki KM-201BAH Ice Maker User Manual


 
30
[b] KM-260BAH
10sec 10sec 10sec 10sec 10sec
10sec 10sec 10sec 10sec 10sec
HARVEST CYCLE
Thermistor senses 9°C
after 6 min to 8 min 50 sec
in harvest cycle (Ver 3.1 or
later)
6min 60sec
HARVEST CYCLE
Thermistor senses 9°C after more than
8 min 50 sec in harvest cycle (Ver 3.1
or later)
6min 3min 10sec
FREEZE CYCLEPART NAME
HARVEST CYCLE
(INITIAL)
FREEZE CYCLE
HARVEST CYCLE
(AFTER BIN FULL)
HARVEST CYCLE
(INCLUDING DRAIN)
FREEZE CYCLE FREEZE CYCLE HARVEST CYCLE BIN FULL
HOT GAS VALVE
FAN MOTOR
ON
OFF
ON
Program Ver 2.5
or earlier
(Auxiliary Code:
V-0 or earlier
)
ON
OFF
WATER VALVE
ON
OFF
CLEANING VALVE
ON
OFF
DRAIN VALVE
FLOAT SWITCH
ON
RELAY: X4
(WV)
ON
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
CONTROL BOARD
RELAY: X6
(DV)
RELAY: X1
(COMP)
RELAY: X2
(HV/FM)
ON
RELAY: X3
(PM)
OFF
OFF
BIN CONTROL
SWITCH
ON
OFF
OFF
PUMP MOTOR
Program Ver 3.2
or later
(Auxiliary Code:
V-1 or later
)
POWER SWITCH
ON
HARVEST CYCLE
COMPRESSOR
ON
OFF
1°C
OFF
9°C
5°C
THERMISTOR
Max 6 min
5 sec
Max 6 min Max 6 min
10 sec
Max 6 min
15 sec
10 sec
90 sec
Max 6
10 sec
10 sec 10 sec
Max 6 min
10 sec
Max 6 min Max 6 min