62
15. FLOAT SWITCH
1) Unplug the icemaker or disconnect the power source.
2) Remove the top panel, rear panel and side panel (R).
3) Disconnect the connector of the fl oat switch lead.
4) Remove the two mounting screws.
5) Install the new fl oat switch in the reverse order of the removal procedure.
6) Refi t the panels in their correct positions.
7) Plug in the icemaker or connect the power source.
Fig. 12
Float Switch