5. Electrical Connection
WARNING
1. Electrical connection must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could result in death,
electric shock, serious injury, re, or extensive damage to equipment.
. THIS UNIT MUST BE GROUNDED. Be sure to install a proper ground from
the icemaker to the remote condenser unit. Use wire of an appropriate gage
and outdoor rating. Failure to properly ground this unit could result in death
or serious injury.
3. The remote condenser unit must be connected to the fan motor junction box
on the icemaker. Use wire of an appropriate gage and outdoor rating. Do not
connect the remote condenser leads to an external power source.
4. To reduce the risk of electric shock, make all remote condenser unit
connections before connecting the icemaker power supply.
5. On remote air-cooled model, the icemaker should have power for a minimum
of 4 hours prior to startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
• The opening for the power supply connection is 7/8" DIA to t a 1/" trade size conduit.
1) Remove the louver panel. See Fig. 9.
) Remove the junction box cover on the remote condenser unit. Remove the fan motor
junction box cover on the icemaker.
3) Install a ground wire from the icemaker to the remote condenser unit. Use wire of an
appropriate gage and outdoor rating.
4) Connect the fan motor leads in the junction box of the remote condenser unit to the fan
motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate
gage and outdoor rating.
5) Replace the junction box covers and the louver panel in their correct positions.
Fig. 9
Screws
Louver Panel
Junction Box
Cover
Remote Condenser Unit
Icemaker
Screw
Fan Motor Junction
Box Cover