31
[a] CLEANING PROCEDURE
1) Dilute approximately 13.5 fl. oz. of recommended cleaner Hoshizaki “Scale Away” or
“LIME-A-WAY,” (Economics Laboratory, Inc.) with 2.5 gallons of water.
2) Remove all ice from the Evaporator and the Storage Bin.
Note: To remove cubes on the Evaporator, turn off the power supply and turn it back on
after 3 minutes. The defrost cycle starts and the cubes will be removed from the
Evaporator.
3) Turn off the power supply.
4) Remove the Front Panel. Then remove the Insulation Panel by removing thumbscrew,
lifting up the panel slightly and pulling it toward you. Remove Cube Guide B by remov-
ing thumbscrew. Remove Cube Guide A. Remove Overflow Cap, Overflow Pipe, and
Water Shield.
5) Remove the Drain Plug located inside the Water Tank. Drain the Water Tank. Replace
the Drain Plug in its correct position.
6) Pour the cleaning solution into the Water Tank.
7) Fully open the Cleaning Valve on the left side wall of the machine compartment.
8) Move the Control Switch, on the Control Box, to the “WASH” position
9) Replace Water Shield, Overflow Pipe, Overflow Cap, Cube Guide A, Cube Guide B, and
Insulation Panel in their correct positions. Replace the Front Panel in its correct
position.
10) Turn on the power supply, and start the washing process.
11) Turn off the power supply after 30 minutes.
12) Remove the Front Panel.
13) Remove the Insulation Panel by removing thumbscrew, lifting up the panel slightly and
pulling it toward you. Remove Cube Guide B by removing thumbscrew. Remove Cube
Guide A. Remove Overflow Cap, Overflow Pipe, and Water Shield.
14) Remove the Drain Plug located inside the Water Tank. Drain the Water Tank. Replace
the Drain Plug in its correct position.
15) Replace Water Shield, Overflow Pipe, Overflow Cap, Cube Guide A, Cube Guide B,
and Insulation Panel in their correct positions.