33
[b] SANITIZING PROCEDURE - Following Cleaning Procedure
1) Dilute a 5.25% Sodium Hypochlorite solution with water (Add approximately 1.25 fl. oz. to
2.5 gal. of water).
2) Remove the Insulation Panel by removing thumbscrew, lifting up the panel slightly and
pulling it toward you.
3) Pour the sanitizing solution into the Water Tank.
4) Replace the Insulation Panel and the Front Panel in their correct positions.
Note: Make sure that the Control Switch is in the “WASH” position
and the Cleaning Valve is open.
5) Turn on the power supply, and start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the Front Panel.
8) Remove the Insulation Panel by removing thumbscrew, lifting up the panel slightly and
pulling it toward you. Remove Cube Guide B by removing thumbscrew. Remove Cube
Guide A. Remove Overflow Cap, Overflow Pipe, and Water Shield.
9) Remove the Drain Plug located inside the Water Tank. Drain the Water Tank. Replace the
Drain Plug in its correct position.
10) Replace Water Shield, Overflow Pipe, Overflow Cap, Cube Guide A, Cube Guide B, and
Insulation Panel in their correct positions.
11) Repeat the above steps 16) through 29) in “[a] CLEANING PROCEDURE” two times to
rinse thoroughly.
12) Close the Cleaning Valve.
13) Move the Control Switch to the “ICE” position.
14) Replace the Front Panel in its correct position.
15) Clean the Storage Bin/Dispenser Unit with water.
16) Turn on the power supply, and start the automatic icemaking process.