6) When the Display Window shows “A 8”, keep on pushing the Set Button. Check that the
Display Window reads “AdJ.”
7) While pushing the Set Button, press the Display Button one time.
8) Check that the Display Window reads “CHE.”, which means the unit is in the check mode.
9) While pushing the Set Button, press the Display Button one more time.
10) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.
11) Release the Set Button.
12) This is the end of adjustment.
A9: Automatic Dispensing Control
1) Follow the steps 1) to 8) in “A1: Cell Lifecycle” to show “A 1” in the Display Window on the
Control Panel.
2) Push the Set Button eight times to show “A 9” in the Display Window.
3) Push the Flush Button one time. The Display Window will flash the present automatic
dispensing control (factory setting: continuous “CoNt.”). Now it is ready for adjustment.
4) To raise the set value, push the Display Button. To lower the set value, push the Flush
Button. The Display Window will flash the changing set value. (For a rapid change, keep
on pushing the Display Button or Flush Button for more than 1 sec.)
5) To determine the set value, press the Set Button one time. The Display Window will stop
flashing and show the set value, then “A 9” which means completion of the adjustment. To
cancel the adjustment, press the Display Button and Flush Button together to show “A 9”
in the Display Window.
6) When the Display Window shows “A 9”, keep on pushing the Set Button. Check that the
Display Window reads “AdJ.”
7) While pushing the Set Button, press the Display Button one time.
8) Check that the Display Window reads “CHE.”, which means the unit is in the check mode.
9) While pushing the Set Button, press the Display Button one more time.
10) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.
11) Release the Set Button.
12) This is the end of adjustment.
Note: If the automatic dispensing control setting is short, the unit may stop automatically in
the middle of the next adjustment. In this case, adjust the setting as follows:
1) Turn on the Power Switch. While the Display Window shows nothing, push the Flush
Button for more than 10 sec.
2) Select the desired mode, and adjust the setting.