2. FUNCTIONS AND ADJUSTMENT OF CHECK ITEMS
The water electrolyzer is provided with the ten check items of the following functions:
No.
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
Check Items
Output Conditions
Input Conditions
Present Average Amperage (A)
Present Stroke Speed (spm)
Present Cell Reverse Time (h)
Last Error Code
Last Error Cell Running Time (h)
Last Error Cell Reverse Time (m)
Last Error Average Amperage (A)
Last Error Stroke Speed (spm)
Functions
Displays all the present output conditions in the
Display Window on the Control Panel.
Displays all the present input conditions in the
Display Window on the Control Panel.
Displays the average amperage at present.
Displays the stroke speed at present.
Displays the cell reverse time at present.
Displays the error code of the last error.
Displays the cell running time of the last error.
Displays the cell reverse time of the last error.
Displays the average amperage of the last error.
Displays the stroke speed of the last error.
CHECKING PROCEDURE
1) Run the electrolyzer to dispense electrolyzed water or to turn on the Add Salt Water Lamp
or the Service Call Lamp.
2) Open the Door.
3) The Display Window on the Control Panel shows the present cell lifecycle, amperage (A)
or voltage (V), or an error code. Keep on pushing the Set Button.
4) Check that the Display Window reads “Nor.”, which means the unit is in the normal mode.