Output to DC power
supply CNT-TOG
12) When the desired check item code is displayed, push the Flush Button one time. The
Display Window will show the present check item information.
13) To finish checking, press the Display Button and Flush Button together to show “C 1”, “C
2”... in the Display Window.
14) When the Display Window shows one of those check item codes, keep on pushing the
Set Button. Check that the Display Window reads “CHE.”
15) While pushing the Set Button, press the Display Button one time.
16) Check that the Display Window reads “Nor.”, which means the device is in the normal
mode.
17) Release the Set Button.
18) This is the end of checking.
C1: Output Conditions
The lighting LED shows the applicable output is ON.
C2: Input Conditions
The lighting LED shows the applicable input is ON.
Direction Microswitch
Location Microswitch
Display Button
Flow Rate Switch
Level Sensor
Flush Button
Set Button
Max. Water Level
(Float Switch ON)
None