Hotpoint RGB528ER Range User Manual


 
...
,.
..___
.—
m&@$!HEgTFMEMH%ETOGM (continued)
:~,1.
Install a manual gas line shut-off valve iu the
;Jgas line in an easily accessed location outside of
the range. Make sure everyone operating the
3
$:range knows where and how to shut off the gas
$=’supply to the range.
s>
2. Install male 1/211flare union adapter to the
1/211N~ internal thread elbow at inlet of
regulator. 0~3 models equipped titi dud
burners9 install male 1/21!flare union adapter to
the I/21tNPT internal thread at inlet of pressure
regu~ator. Use a backup wrench on the regulator
fitting to avoid damage.
f~en installing the range from the front, remove
the 90° elbow for easier installation.
3. Install male 1/2’1or 3/411flare union adapter to
the NTPTinternal thread ofthe manual shut-off
valve, taking care to back-up the shut-off valve to
keep it from turning.
4. Connect flexible metal appliance connector to
the adapter on the range. Position range to permit
connection at the shut-off valve.
5. When all connections have been made, make
sure all range controls are in the off position and
turn on the main gas supply valve. Use a liquid
leak detector at alljoints and connections to
check for leaks in the system.
e~mo~:DO ~o~usE A HE To
CHECK FOR GM ~e
$
~men using test pressures greater than 1/2 psig
to pressure test the gas supplysystel~~ofthe
residence, disconnectthe range and individual
shut-offvalvefrom the gas supplypiping.When
using test pressures of 1/2 psig or less to test the
gas SUpplysystem, simplyisolate the ra:ge from
the gas supply system by closing the individual
shut-offvalve.
Because ofpotentialsafetyhazards associated
withcertain conditions,we stronglyrecommend
againstthe use ofan extension cord. However, if
you stillelect to use an extensioncord, it is
absolutelynecessary that it be a UL-listed,3-wire
grounding-typeapplianceextension cord and that
the current carrying rating ofthe cord in
amperes be equivalentto, or greater than, the
branch circuitrating.
The power cord ofthis applianceis equippedwith
a three-prong (grounding)plug which mates with
a standard three-prong grounding wallreceptacle
to minimizethe
m
PREFERRED r
rAETtioD
possibilityof
Q
Q
electric shock
<8>
%
hazard from this
appliance.
/
~,
The customer
should have the
NSURE PROPER
ROUNDEXISTS
wallreceptacle
EFORE USE
and circuit
checked by
~1~~
a qualti~ed-
electrician to make sure the receptacle is
properly grounded.
Where a standard two-prongwallreceptacle is
encountered, it is the personal responsibility and
obligationofthe customer to have it replaced with
a properly grounded three-prong wallreceptacle.
Do NOT, mDER m cIRcuMwmQEs,
Cm OR ~MOW ~E
m~m(GROUND)
PRONGmoMmE
~Om~ cOm.
... ..%
—-.—... ...