Cornelius 500 - Series Ice Maker User Manual


 
Continuous Flow Icemaker Service Manual
© 2004-2005, IMI Cornelius Inc. - 15 - Publication Number: 630460174SER
MOTOR CHECK
The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low
readings must be used. The start relay cover must be removed.
If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test,
replace gearmotor.
START RELAY
1. Check between 2 and 4 on relay (with relay unplugged). If there is continuity replace the relay, as
the relay contacts should be open.
2. Check between 3 and 4 on relay, if no continuity replace the relay.
FIGURE 14. GEARMOTOR ASSEMBLY
TO REPLACE GEARMOTOR ASSEMBLY
1. Disconnect the icemaker from the electrical power source.
2. Disconnect the transmission cable from the electrical box.
3. Remove the 4 hex head bolts securing the evaporator to the top of the transmission.
4. Remove the 4 bolts holding the transmission and bracket to frame base, while supporting the
weight of the evaporator. Remove the transmission from the unit.
5. When replacing the transmission, it may be necessary to rotate the auger back and forth to align
the motor shaft and auger.
FIGURE 15. AUGER AND EXTRUDING HEAD REMOVAL
AUGER NUT
BEARING NYLON
GROOVE
EXTRUDING
HEAD
BEARING DELRIN
ANTI–ROTATION
RIB – 3 PLACES
AUGER
“D” DRIVE