TROUBLESHOOTING
TROUBLESHOOTING
Trouble Probable Cause Remedy
WATER-TO-SYRUP ‘‘RATIO’’
TOO LOW OR TOO HIGH
A. Dispensing valve syrup flow
regulator not properly
adjusted.
A. Adjust Water-to-Syrup ‘‘Ratio’’ of
dispensed drink as instructed.
B. CO
2
gas pressure to syrup
tanks insufficient to push syrup
out of tank or to pump from the
B-I-B container.
B. Adjust syrup tanks secondary
CO
2
regulator as instructed.
ADJUSTMENT OF
DISPENSING VALVE SYRUP
FLOW REGULATOR DOES
NOT INCREASE TO DESIRED
WATER-TO-SYRUP ‘‘RATIO’’
A. Dispensing valve syrup flow
regulator, syrup tank quick
disconnect, or syrup line
restricted.
A. Sanitize syrup system as
instructed.
B. Syrup tank quick disconnects
not secure.
B. Secure quick disconnects.
C. Syrup tanks secondary CO
2
regulator out of adjustment.
C. Adjust syrup tanks secondary
CO
2
regulator as instructed.
D. No syrup supply. D. Replenish syrup supply.
E. Improper syrup Baume. E. Replace syrup supply.
F. Dirty or inoperative piston or
spring in dispensing valve
syrup flow regulator.
F. Disassemble and clean
dispensing valve syrup flow
regulator.
G. Tapered nylon washer inside
tube swivel nut connector
distorted from being
overtightened.
G. Replace nylon washer and make
sure it seats properly.
ADJUSTMENT OF
DISPENSING VALVE SYRUP
FLOW REGULATOR DOES
NOT DECREASE TO
DESIRED WATER-TO-SYRUP
‘‘RATIO’’
A. Dirty or inoperative piston or
spring in dispensing valve
syrup flow regulator.
A. Disassemble and clean
dispensing valve syrup flow
regulator.