Trouble Probable Cause Remedy
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING VALVE
A. Dispensing valve restricted
or dirty.
A. Sanitize syrup system as
instructed.
B. Tapered nylon washer inside
carbonated water line swivel
nut connector distorted
restricting carbonated water
flow.
B. Replace nylon washer. Make sure
it is properly seated.
C. Dirty water supply. C. Check water filter. Replace
cartridge. (see NOTE)
D. Warm Product - No ice in bin,
bridged ice on cold plate or
plugged drain.
D. Replenish ice, break ice up to
eliminate bridging, unplug the
drain.
NOTE: If water supply is dirty, be sure to flush lines and carbonator completely. It may be necessary to
remove lines to carbonator tank, invert tank, and flush tank and all inlet lines to remove any foreign
particles or dirt.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES
A. Transformer unplugged. A. Plug in the transformer.
B. No electrical power to
transformer.
B. Check fuse or circuit breaker.
C. Disconnected dispensing
valves power cord.
C. Connect dispensing valves
power cord.
D. Disconnected or broken wiring
to dispensing valves.
D. Connect or replace wiring.
E. Inoperative transformer. E. Replace transformer as
instructed.
NO PRODUCT DISPENSED
FROM ONE DISPENSING
VALVE
A. Broken or disconnected wiring. A. Repair or connect wiring.
B. Inoperative dispensing valve
solenoid coil.
B. Replace solenoid coil as
instructed.
C. Inoperative dispensing valve
micro switch.
C. Replace micro switch as
instructed.