VALVE SERVICE
NOTE: Before servicing the valve the BIB connector must be disconnected an the pressure must
be relieved.
1. Remove the locking screw after removing the valve from its mounting block.
2. Twist the solenoid 90
o
.
3. Pull the solenoid loose from the valve body.
4. To remove the tubing squeeze the spring
clip together and pull off.
FIGURE 19
CARBONATOR TANK
Always disconnect water and CO
2
and relieve
the carbonator pressure before removing the car-
bonator probe.
FIGURE 20
MOTOR REMOVAL
NOTE: Apply anti seizing lubricant to the
threads of mounting bolts when service is
required.
FIGURE 21
Spring Clip
Locking Screw
Grounding Connection/
CO2 Inlet
Upper and Lower Level
Control Probes
Relief
Valve
Heater, Agitation
Motor, & Gear Box
Heater Spring
Motor
Mounting
Screws