Dispenser Troubleshooting
Symptom Cause Remedy
Blown fuse or circuit
breaker
Short circuit in electrical wiring Repair Wiring
Inoperable agitator motor (shorted
motor)
Replace gear motor
Agitator does not
turn
No power Restore power or plug in unit
Improperly installed upper ice chute
assembly (Reed switch is not being
activated)
Check the upper ice chute assembly for
proper assembly and operation
Inoperable reed switch Replace reed switch
Electrical board driver circuit is
defective
Replace main control board
Gear motor has open circuit Replace gear motor
Reed switch is not activated Improper
assembly of upper ice chute to lower
chute.
Check to make sure tongue of upper
chute engages into the back of the
lower chute, ensure upper chute
engages outside the lower chute, and
snap front of chute into place.
Broken wire in the 2-wire harness
leading to the reed switch
Repair of replace 2-wire harness
Bad connection at main control board,
J3, pins 2 &3
Repair connection or replace 2-wire
harness
Ice dispenses
continuously
Ice gate mechanism is stuck in open
position
Inspect gasket for proper position.
Examine gate plate to see if it slides
freely behind the lower ice chute.
Stuck or bent ice lever (does not allow
gate to close and open reed switch)
Examine ice dispense lever to see if it is
bent.
Slushy ice or water
in hopper
Blocked drains in cold plate Remove access covers in cold plate
cover & inspect/clean drains
Poor ice quality due to water quality or
ice maker problems
Correct water quality or repair ice maker
Beverage does not
dispense
No 24VAC to valves Restore 24 VAC to valves
No CO
2
pressure Restore CO
2
pressure
Beverage is too
sweet
Valve brix requires adjustment Adjust valve brix
Carbonator is not operating Repair carbonator
No CO
2
in carbonator Restore CO
2
pressure in carbonator