Jackson 300XS Dishwasher User Manual


 
300X Series Technical Manual 7610-002-64-22
Issued: 07-26-2006 Revised: N/A
SECTION 5: SERVICE PROCEDURES
RINSE REGULATING THERMOSTAT REPLACEMENT
29
Remove the thermostat bracket mounting nuts with the 3/8”
nutdriver.
5. Attach the jumper wires to the wires that you removed from
the old thermostat.
Removing the imperial brass fitting (Tempstar).
Location of the thermostat bracket (JP-24).
Location of the imperial brass fitting (JP-24).
Attaching the jumper wires.
Pulling the thermostat probe and fitting from the well (Tempstar).
Removing the wires from the thermostat.