Jackson 300XS Dishwasher User Manual


 
300X Series Technical Manual 7610-002-64-22
Issued: 07-26-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
300X
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 50 12 KW@240V 71 90 AMP
208 1 50 14 KW@240V 78 100 AMP
230 1 50 12 KW@240V 78 100 AMP
230 1 50 14 KW@240V 86 110 AMP
208 3 50 12 KW@240V 45 60 AMP
208 3 50 14 KW@240V 49 70 AMP
230 3 50 12 KW@240V 48 60 AMP
230 3 50 14 KW@240V 53 70 AMP
380 3 50 12 KW@380V 29 40 AMP
*380 3 50 14 KW@208V 34 45 AMP
415 3 50 12 KW@415V 26 35 AMP
415 3 50 14 KW@415V 29 40 AMP
440 3 50 12 KW@460V 21 30 AMP
440 3 50 14 KW@460V 25 35 AMP
208 1 60 12 KW@240V 69 90 AMP
208 1 60 14 KW@240V 76 100 AMP
230 1 60 12 KW@240V 76 100 AMP
230 1 60 14 KW@240V 84 110 AMP
208 3 60 12 KW@240V 43 60 AMP
208 3 60 14 KW@240V 47 60 AMP
230 3 60 12 KW@240V 46 60 AMP
230 3 60 14 KW@240V 51 70 AMP
460 3 60 12 KW@480V 22 30 AMP
460 3 60 14 KW@480V 24 30 AMP
300XN
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 50 N/A 28 35 AMP
230 1 50 N/A 30 40 AMP
208 3 50 N/A 20 25 AMP
230 3 50 N/A 21 30 AMP
380 3 50 N/A 10 15 AMP
415 3 50 N/A 10 15 AMP
440 3 50 N/A 8 15 AMP
208 1 60 N/A 26 35 AMP
230 1 60 N/A 28 35 AMP
208 3 60 N/A 18 25 AMP
230 3 60 N/A 28 35 AMP
460 3 60 N/A 8 15 AMP
300XLT
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 50 N/A 28 35 AMP
230 1 50 N/A 30 40 AMP
208 3 50 N/A 20 25 AMP
230 3 50 N/A 21 30 AMP
380 3 50 N/A 10 15 AMP
415 3 50 N/A 10 15 AMP
440 3 50 N/A 8 15 AMP
208 1 60 N/A 26 35 AMP
230 1 60 N/A 28 35 AMP
208 3 60 N/A 18 25 AMP
230 3 60 N/A 28 35 AMP
460 3 60 N/A 8 15 AMP
300XS
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 50 N/A 7 15 AMP
230 1 50 N/A 7 15 AMP
208 3 50 N/A 7 15 AMP
230 3 50 N/A 7 15 AMP
380 3 50 N/A 7 15 AMP
208 1 60 N/A 6 15 AMP
230 1 60 N/A 6 15 AMP
208 3 60 N/A 6 15 AMP
230 3 60 N/A 6 15 AMP
460 3 60 N/A 2 15 AMP
* This unit is wired in a wye configuration for the heaters.
3
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip
circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is dis-
played here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all
applicable national and local codes. These numbers are provided in this manual simply for reference and may change with-
out notice at any given time.