OperatingParameters
ModelDesignation:44”66”44”Steam66”Steam
OperatingCapacity:
RacksperHour218218218218
DishesperHour 3488348834883488
GlassesperHour 7848784878487848
TankCapacity(gallons):
WashTank 35.635.635.635.6
Pre‐WashTankN/A15.8N/A15.8
ElectricalLoads(asapplicable):
WashMotorHP 3.03.03.03.0
DriveMotorHP0.250.250.250.25
Pre‐WashMotorHPN/A2.0N/A2.0
WashHeaterKW15or1818N/AN/A
NOTE:Alwaysrefertothemachinedataplateforspeciicelectricalandwaterrequirements.The
materialprovidedonthispageisforreferenceonlyandissubjecttochangewithoutnotice.
HOTWATERSANITIZING
Water
Temperatures(Fahrenheit):
Pre‐WashTemperature(Recommended)N/A110‐140N/A110‐140
MinimumWashTemperature 160160160160
MinimumRinseTemperature 180180180180
IncomingWaterTemperature
12KWBooster 140140N/AN/A
18KWBooster 110110N/AN/A
NoBooster180180180180
CHEMICALSANITIZING
WaterTemperatures(Fahrenheit):
Pre‐WashTemperature(Recommended)N/A110‐120N/A
110‐120
MinimumWashTemperature 120120120120
MinimumRinseTemperature 120120120120
IncomingWaterTemperature
12KWBooster 8080N/AN/A
18KWBooster5050N/AN/A
NoBooster120120120120
OtherWaterRequirements:
WaterFlowPressure(PSIG) 15151515
FlowRateMinimum(GPM)1.181.181.181.18
WaterLineSize(NPT) 1/2”1/2”1/2”1/2”
DrainLineSize(NPT) 1‐1/2”1‐1/2”1‐1/2”1‐1/2”
SteamRequirements
SteamLineforWashTank(NPT)N/AN/A3/4”3/4”
SteamFlowPressure(PSIG)N/AN/A10‐2010‐20
Consumption@15PSIG(lbm/hr)N/AN/A6060