13
PageCreated:05‐04‐2010
Revised:02‐25‐2011
TechnicalManual(07610‐003‐78‐18)
NotesRegardingElectricalRequirements
Allelectricalratingsprovidedinthismanualareforreferenceonly.Alwaysrefertothemachinedataplate
togettheexactelectricalinformationforyourmachine.Allelectrical work performed onmachines
shouldbedoneinaccordancewithapplicablelocal,state,territorialandnationalcodes.Workshould
onlybeperformedbyqualiiedelectriciansandauthorizedserviceagents.AlistofauthorizedServiceAgen‐
ciesislocatedinthebackofthismanual.
Note that all electrical wiring used in the dish‐machine must be rated, at a minimum, for 100C (212F).
Furthermore,usecopperconductorsonly.
Whereapplicable,heatingelementamperagedrawshavebeenadjustedfortheassumedinputvoltage.Jack‐
sonassumesincomingvoltageswillbeeither208,230or460volts.Someoftheheatingelementsusedin
ourmachinesareactuallyratedforothervoltages,suchas240or480volts.Alwaysverifytheamperage
drawofthemachineinoperationwhensizingcircuitprotection.
Ifyourmachineisequippedwiththeoptionalrinseheater,notetherinseheaterhasitsownelectricalcon‐
nectionandthereforerequiresaseparateservice.Amperageloadsformotorsandheatersarecalledouton
themachinedataplatefortheinstallation/servicetechnician.
Theelectricalconigurationsofthemachinesareasfollows:
AvailableElectricalCharacteristics:
208volt,60Hz,singlephase
230volt,60Hz,singlephase
208volt,60Hz,threephase
230volt,60Hz,threephase
460volt,60Hz,threephase
AvailableWashTankHeaters:
15KW(standardforCREW44)
18KW(optionalforCREW44,standardforCREW66)
AvailableRinseHeaters(“BoosterHeaters”):
None(standard)
12KW(40Friseintemperature)
18KW(70Friseintemperature)