Jackson JFT Dishwasher User Manual


 
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
3" [76mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load or
unload end of the machine.)
1
7
6
Control Cabinet Door Open
Doors In The Open Postion
Power Connections Inside Control Panel
2
3
4
5
TYPICAL
Top of Exhaust Fan Housing
6
1
2
3
4
5
6'-10" [2083mm]
9'-6" [2896mm]
10
3
4
" [273mm]
3' [914mm]
5'-4
3
4
" [1644mm]
6" [152mm]
5
1
8
" [129mm]
15'-5
1
2
" [4712mm]
13'-6" [4115mm]
12'-7" [3836mm]
6" [152mm]
8
7
8
" [226mm]
3' [914mm]
6'-1" [1855mm]
9'-2" [2794mm]
18'-6" [5639mm]
3'-6" [1067mm]3' [915mm]3' [914mm]3' [914mm]3' [914mm]3' [914mm]
9" [229mm]
1'-7
1
8
" [486mm]
3' [914mm]
3'-2
1
4
" [972mm]
6'-4
1
2
" [1943mm]
15'-5
1
2
" [4712mm]
13'-6" [4115mm]
12'-7" [3836mm]
2'-5
3
8
" [746mm]
2'-4
3
8
" [721mm]
1'-7
1
8
" [486mm]
3'-2
1
4
" [971mm]
3'-5
1
4
" [1048mm]
3'-10" [1168mm]
DIRECTION OF OPERATION
7
7'-6" [2286mm]
Optional - Short Doors In The Open Position
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
1'-2
3
4
" [375mm]
2'-3
3
4
" [706mm]
3" [76mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load or
unload end of the machine.)
9
1
4
" [234mm]
2'-5
1
4
" [743mm]
Control Cabinet Door Open
7
6
4
5
2
3
1
3" [72mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load or unload
end of the machine.)
Doors In The Open Position
1
Typical
6
Top of Exhaust Fan Housing
Power Connections Inside Control Panel
2
3
4
5
DIRECTION OF OPERATION
1'-7
1
8
" [486mm]
3'-2
1
4
" [971mm]
3'-5
1
4
" [1048mm]
3'-10" [1168mm]
2'-4
3
8
" [721mm]
2'-5
3
8
" [746mm]
12'-7" [3836mm]
13'-6" [4115mm]
15'-5
1
2
" [4712mm]
9" [229mm]
1'-7
1
8
" [486mm]
3' [914mm]
3'-2
1
4
" [972mm]
6'-4
1
2
" [1943mm]
3' [914mm]3' [914mm]3' [914mm]3' [914mm]3' [915mm]3'-6" [1067mm]
18'-6" [5639mm]
9'-6" [2896mm]
9'-2" [2794mm]
6'-1" [1855mm]
3' [914mm]
8
7
8
" [226mm]
6" [152mm]
12'-7" [3836mm]
13'-6" [4115mm]
15'-5
1
2
" [4711mm]
5
1
8
" [129mm]
6" [152mm]
10
3
4
" [273mm]
3' [914mm]
5'-4
3
4
" [1644mm]
6'-10" [2083mm]
7
7'-6" [2286mm]
Optional - Short Doors In The Open Position
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
3" [72mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load
or unload end of the machine.)
2'-3
3
4
" [706mm]
1'-2
3
4
" [375mm]
9
1
4
" [234mm]
2'-5
1
4
" [743mm]
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Electric requirements with booster and blower dryer
KW 208V 230V 460V
Wash 24 76.3 69.9 36.0
Rinse 26 77.8 70.8 35.4
Blower Dryer, Motors and Controls 20 43.7 41.4 20.7
Booster 27 75.0 67.8 33.9
Total 272.8 249.9 126
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Electric equirements with booster
KW 208V 230V 460V
Wash 24 76.3 69.9 35.0
Rinse 26 77.8 70.8 35.4
Motors and Controls 12.2 12.3 6.2
Booster 27 75.0 67.8 33.9
Total 241.3 220.8 110.5