Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
Steam
Control Cabinet Door Open
3" [72mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load
or unload end of the
machine.)
PREWASH
SECTION
WASH
SECTION
POWER RINSE
SECTION
CONTROL
CABINET
DIRECTION OF OPERATION
Top of Condensate Duct Pan
5
6
Doors In The Open Position
1
4
3
7
2
8
1
5
6
2
3
8
7
4
6'-4
1
2
" [1945mm]
3'-2
1
4
" [972mm]
3'-0
5
8
" [930mm]
2'-4
1
2
" [724mm]
1'-7
1
8
" [486mm]
10" [254mm]
9" [229mm]
3'-6" [1067mm]3' [914mm]3' [914mm]3' [915mm]
3' [913mm]3' [914mm]
15'-5
1
2
" [4712mm]
2'-4
3
8
" [719mm]
2'-5
3
8
" [745mm]
7'-8" [2335mm]
10'-8" [3250mm]
12'-7
1
4
" [3840mm]
13'-6" [4115mm]
14'-6" [4420mm]
1'-7
1
8
" [486mm]
3' [914mm]
3'-2
1
4
" [972mm]
3'-5
1
4
" [1048mm]
3'-10" [1168mm]
18'-6" [5639mm]
9'-6" [2896mm]
6'-10" [2084mm]
5'-4
3
4
" [1644mm]
3' [915mm]
1'-1
1
2
" [343mm]
10
3
4
" [273mm]
8
5
8
" [219mm]
6" [152mm]
7'-8" [2335mm]
10'-8" [3250mm]
12'-7
1
4
" [3843mm]
13'-6" [4115mm]
14'-6" [4420mm]
15'-5
1
2
" [4712mm]
6" [152mm]
8
7
8
" [226mm]
10" [253mm]
6'-1" [1855mm]
9'-2" [2794mm]
7'-6" [2286mm]
Optional - Short Doors In The Open Position
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
3"[76mm] Minimum
Floor Sink or Floor Drain
(Optional to drain at load or
unload end of the machine.)
1'-2
3
4
" [375mm]
2'-3
3
4
" [705mm]
A.F.F.
Exhaust Requirements
- 1200 CFM
6'-10" [2083mm]
3" [72mm] Deep
18" [457mm] I.D. Square
Condensate duct pan mounted on top of
dishmachine electrical section.
Condensate Exhaust Duct
Minimum 18" Square (Cross Section 324 Sq. In.)
Provided by HVAC Contractor
Condensate duct to extended into duct pan.
Note:
The condensate removal system built into the dishmachine consists of a fan
that will remove 1200 CFM. A single condensate connection must be provided
by the installing contractor. This is an indirect connection that must be capable
of removing 1200 CFM from the area.
Legend
1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end)
2 - Electrical Connection - See Table for Amp Draw
3 - 3/4" NPT Incoming Water Connection
4 - 1-1/2" NPT Steam Connection
5 - 3/4" NPT Wash Section Condensate Return
6 - 3/4" NPT Power Rinse Section Condensate Return
7 - 3/4" NPT Booster Heater Condensate Return
8 - Condensate Connection - See Detail