Jenn-Air 36 Range User Manual


 
6
5. Any openings in the wall behind the range and in the
floor under the range must be sealed.
6. When there is less than a 12² clearance between
combustible material and the back edge of the range,
(above the cooking surface) Jenn-Air Stub Back or
High Shelf Backguard must be installed. These parts
must be ordered separately, except for the PRG3010
which comes equipped with a Low Back. Figure 3A
and Figure 3B indicate the space required for each
type of backguard.
7. Always keep the appliance area clear and free from
combustible materials, gasoline and other flammable
vapors and liquids.
8. Do not obstruct the flow of combustion and ventilation
air to the unit.
H
2-1/2²
2-1/2²
1-3/4²
G
10²
10²
9-3/8²
DIMENSIONS
PRG4810
PRG3610
PRG3010
C
12²
12²
9²
D
21-1/4²
21-1/4²
21-1/4²
E
29-15/16²
29-15/16²
29-15/16²
F
28-3/16²
28-3/16²
28-3/16²
B
44-11/16²
44-11/16²
44-1/4²
A
27-7/16²
27-7/16²
26-3/4²
FIGURE 3BFIGURE 3A
36² Min. To
Combustibles
High Shelf
Low Back
0² Clearance 0² Clearance
F
G
H
D
C
A
E
B
36² Min. To
Combustibles
12² Min. To Combustibles
Without Backguard
1-1/2²
Island T rim
TABLE 2