Jenn-Air’s ventilation system is designed to capture both cooking fumes and smoke from any
place on the grill surface. If the system does not, these are some ducting installation situations
to check:
0 6” diameter round or 3’/4” x10” rectangular ducting should be used. Note: 5” diameter
round ducting may be used for venting straight out of the back of the cooktop and directly
through the wall for 10’ or less.
0 No more than three 90” elbows should be used. Distance between elbows should be at
least 18”.
0 Recommended Jenn-Air wall cap should be used. Make sure damper moves freely when
ventilation system is operating.
0 There should be a minimum clearance of 6” for cooktop installed near a side wall.
If there is not an obvious improper installation, there may be a concealed problem such as a
pinched joint, obstruction in the pipe, etc. Installation is the responsibility of the installer and
questions should be addressed first by the installer. The installer should very carefully check
the ducting installation instructions.