Jenn-Air CVG4380P Cooktop User Manual


 
Jenn-Air's ventilation system is designed to capture both cooking fumes and smoke
while grilling. If the system does not, these are some ducting installation situations to
check:
6" diameter round or 31/4' x 10" rectangular ducting should be used for duct lengths
10'-60'. Note: 5" diameter round ducUng must be used if the duct length is 10'
or less.
No morethan three 900elbowsshouldbe used. Distancebetween elbows should
be at least 18".
RecommendedJenn-Airwallcap shouldbe used. Make suredamper movesfreely
when ventilationsystemisoperating.
There shouldbe a minimumclearance of 6" for cooktop installed near a side wall.
If there is not an obviousimproperinstallation,there may be a concealed problemsuch
as a pinched joint, obstructionin the pipe, etc. Installationis the responsibili_ of the
installerandquestionsshouldbeaddressedfirstbythe installer.The installershouldvery
carefullycheck the ducting installationinstructions.
19