Jenn-Air’s ventilation system is designed to capture both
cooking fumes and smoke from the cooktop surface. If the
system does not, here are some ducting installation situations
to check:
6” diameter round or 3
1
/
4
” x 10” rectangular ducting should
be used for duct lengths 10’-60’.
There should be a minimum clearance of 6” for cooktop
installed near a side wall.
If there is not an obvious improper installation, there may be a
concealed problem such as a pinched joint, obstruction in the
pipe, etc. Installation is the responsibility of the
installer and questions should be addressed
first by the installer. The installer should very
carefully check the ducting installation instruc-
tions.
Use the Flow Tester Card provided with your
appliance to check the air flow.