Jenn-Air JDR8895ACS/W Double Oven User Manual


 
Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.
©2004 Maytag Services 16023417 19
“Quick Test” Mode for Electronic Range Control
Follow the procedure below to perform the Electronic Range Control (ERC) quick test. Instructions must be entered
within 32 seconds of each other (via the touch pad) or the ERC will exit the quick test.
1. Press and hold the
UPPER
CANCEL
and
BROIL
pads for 3 seconds.
2. Once the control has entered the “Quick Test” mode, release both pads.
3. Press each of the following pads indicated in the table below.
NOTE: Press the applicable pad once to activate the associated response.
Press the applicable pad a second time to deactivate the associated response.
Display indicates the following:
Pad Response
BAKE................................... Bake DLB and Bake relay activated
BROIL.................................. Broil DLB and Broil relay activated
KEEP WARM ...................... Bake DLB and Broil DLB activated
CONVECT BAKE ................ Convection Fan on low speed
CONVECT ROAST ............. Convection Fan on high speed
CLEAN................................. MDL relay activated
COOK & HOLD ................... Displays last diagnostic code
FAVORITE .......................... Displays EEPROM version number
TIMER ................................. Displays main code version number
CLOCK ................................ All display segments illuminated
OVEN LIGHT....................... Oven light activated
CANCEL.............................. Exit Quick Test mode
1........................................... Even segments on
2........................................... Odd segments on
3........................................... Convection Ring activated; Convection Ring DLB activated
4........................................... N/A
5........................................... N/A
6........................................... N/A
7........................................... N/A
8........................................... N/A
9........................................... N/A
AUTOSET ........................... Steps through last 5 diagnostic codes
Setup Options
(0)
pad is pressed “Press Desired Pad for Selection” will scroll in the display. When a feature is
displayed the
AUTO SET
pad is used to toggle the options. Use the chart below to identify the available options.
Control
Function
Pad
Selection
Default Option Additional Options
12 hour shut-off 1 12 HR Energy Saver ON 12 HR Energy Saver OFF
Timer beeps 2 Timer Reminder Beeps for 5 Min. Timer Reminder Beeps for 30 Min.
No Timer Reminder Beeps
Cook time beeps 3 Cook Time Reminder Beeps for 30 Min. Cook Time Reminder Beeps for 5 Min.
No Cook Time Reminder Beeps
Control lock 4 Control Unlocked Control Locked
Scroll speed 5 Medium Speed Fast Speed Slow Speed
Volume level 6 6 bars 1 to 8 bars
Temp C/F 7 Degrees F Degrees C
Language 8 English French, Spanish
Default 9 Press AUTO SET for Factory Settings N/A
Display On/Off Clock Clock Display is ON Clock Display is OFF