Jenn-Air W10394575A Range User Manual


 
21
Natural Gas Conversion
1. Turn the manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
1. Remove screws from kick plate.
2. Push up on kick plate to release plate from shoulder screws.
3. Gently lay kick plate aside to avoid scratching the stainless
steel.
4. Locate the gas pressure regulator at the left rear of the range.
5. Remove the gas pressure regulator cap by using a large flat-
blade screwdriver, turning the regulator cap
counterclockwise.
NOTE: Do not remove the spring beneath the cap.
6. Turn over the gas pressure regulator cap and reinstall on the
regulator so that the hollow end faces out and the letters
“NAT” are visible.
7. Tighten the gas pressure regulator cap by using a large flat-
blade screwdriver, turning the regulator cap clockwise.
8. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
Natural Gas:
Minimum pressure 6" (15.2 cm) WCP
Maximum pressure 14" (35.6 cm) WCP.
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1" water column pressure above the manifold pressure
shown on the model/serial rating plate.
A.To range
B. Shutoff valve (closed position)
C.Gas supply line
A.Kick plate
B.Remove these screws.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A
B
A. Gas pressure regulator
A