Kenmore 73511 Range User Manual


 
nsta Uation Instructions (continue€
9÷p 8
BnstaHing the Anti-Tip Device
WARNING:
o Range must be secured with an approved Anti-
Tip device,
o Unless properly installed, the range could be
tipped by an adult or a child standing, sitting or
leaning on an open door or drawer
o After installing the Anti-Tip device, make sure it
is in place by carefully attempting to tilt the range
forward
o This range has been designed to meet all recog-
nized industry tip standards for all normal conditions
o The use of this device does not preclude tipping
of the range when not properly installed
If the Anti-Tip device supplied with the range
does not fit this application, use the universal Anti-
Tip device WB02X7909,
1. Mark the wall where the RIGHT EDGE of the range
is to be located Be sure to allow for the countertop
overhang if you intend to install the range next to cab-
inets.,
|
An,i-Tip1
-" I]Device ]
Slotled _ t !lt-:_._.._
Head _3_,,_, UIj, 1I
crow l 1-Tl!Wo,,p,a,o]
Appro×20 _dZL[J_ I
7 ,31/_. .. Marked Edge
/" (_ 78 /-- of Range
2. Locate the outside edge of the device 2¼" toward the
center of the range from the marked edge of the range,
3. Using the device as a template, mark the position of
the hole for the screw
Wallboard
Back of
Range
Anti-Tip
Device
Wood Screw
Anti-Tip Bracket
4. For wood construction, drill a pilot hole at an
angle of 20 degrees from the horizontal A nail or awl
may be used if a drill is not available
Mount the Anti-Tip device with the screw provided.
For cement or concrete construction, you wil! need
a 1/4" x 1W' lag bolt and a 1/2" O.D. sleeve anchor,
which are not provided Drill the recommended size
hole for the hardware.
Install the sleeve anchor into the drilled hole and then
install the lag bolt through the device. The bolts must be
properly tightened as recommended for the hardware.
5. Slide the range against the wall, and check for
proper installation by grasping the front edges of the
rear surface unit openings and carefully attempting to
tilt the range forward°
WHEN ALL HOOKUPS ARE COMPLETED
MAKE SURE ALL CONTROLS ARE LEFT IN
THE OFF POSITION.
MAKE SURE THE FLOW OF COMBUSTION AND
VENTILATION AIR TO THE RANGE IS UNOB-
STRUCTED.
10