staHation nst uctions (oont n0e¢
Convert The Oven Burner Orifice
For LP Gas
Oven Burner:
1. Remove oven door, storage drawer, oven bottom
and burner baffle.. The burner orifice spud is located
behind a metal shield at the center bottom of range.
2. Remove metal shield and use a 1/2" wrench to turn
the burner orifice spud clockwise Tighten spud only
until it is snug with the base To prevent leakage, do
not overtighten spud or loosen spud after it is snug
St®p 4
Adjusting The ABrAdjustment Shutters
For LP Gas
For location of and access to air adjustment shutters,
see page 8.
Loosen the Phillips head
screw and rotate the shutter
to the full open position. With
baffle in place, flames should
have approximately 1-inch
blue cones and should not
extend beyond the edges of
the burner baffle For LP
gas, this should occur when
the air adjustment shutter is
completely open After 30
seconds of burner operation, check for flames lifting
off burner ports. If lifting is observed, gradually reduce
air shutter opening untit flames are stabifized.
Broil Burner:
Use a 1/2" wrench to turn the upper burner orifice
spud clockwise Tighten spud only until it is snug with
the base To prevent leakage, do not overtighten spud
or loosen spud after it is snug
12