Kenmore 795.7109 Refrigerator User Manual


 
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.9 lpm)
Water Supply Potable Water
Water Pressure 40-120 psi (138 - 827 kPa)
Water Temperature 33°F - 100°F (0.6°C - 38°C)
it is essential that the manufacturer's recommended
installation, maintenance and water filter replacement
requirements be carried out for the product to perform as
advertised.
NOTE: While the testing was performed under standard
laboratory conditions, actual performance may vary.
For estimated costs of replacement elements, please call
1-800-469-4663 or visit our website at
www.sears.com/partsdirect
3M is a trademark of 3M Company.
NSF is a trademark of NSF International.
© 2009 3M Company. All rights reserved.
To reduce the risk associated with ingestion of
contaminants: Do nat use with water that is
mlcrobialoglcally unsafe or of unknown quality
without adequate disinfection before and after of the
system. Systems certified for cyst reduction may be
used on disinfected water that may contain filterable
cysts. EPA Establishment Number 10350-MN-005
To reduce the risk associated with property damage
due to water leakage:
Read and follow the Water Filter instructions before
installation and use of this system.
Installation and use MUST comply with all state and
local plumbing codes.
Do not install if water pressure exceeds 120 psi (827
kPa)o Contact a plumbing professional if you are
uncertain of how to check your water pressure.
Do not install where water hammer conditions may
occur. If water hammer conditions exist, you must
install a water hammer arrestero Contact a plumbing
professional if you are uncertain of how to check for
this condition.
* Do not install on hot water supply lines.
The maximum operating water temperature of this
water filter system is 100°F (38°C).
* Pratectwater filterfrom freezing.Do not operate
refrigerator in ambient conditions below 55°F
(12.7 C). Drain water filter when storing unit in
temperatures below 40°F (4.4°C).
The disposable water filter must be replaced by one
of the same rated capacity every six months, or if a
noticeable reduction in flow rate occurs.
3O
MFL62184418 DDDDD.indd 30 2011.4.7 3:7;22 PM