Kenmore ULTRAFILTER 500 Water Dispenser User Manual


 
- STEP 1: INSTALL COLD WATER SUPPLY FITTING -
Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The
fitting must provide a leak-tight connection to the RO 1/4" tubing (see FIG. 8, page 8). A typical connection
using the included water supply fitting is shown in FIG.3 - A below. An optional connection, using standard
plumbing fittings (not included), is shown in B.
Note: Codes in the state of Massachusetts require installation by a licensed plumber, and do not permit the use of a saddle
valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
A. WATER SUPPLY FITTING
1. Close the house main water shutoff valve and open
faucets to drain water from the sink cold water pipe.
2. Remove nut that connects the cold water faucet to
cold water plumbing.
3. Use pipe joint compound or Teflon tape on cold water
faucet stud threads and on the male threads of the water
supply fitting that connect to the cold water pipe.
4. Thread water supply fitting onto pipe and reconnect
nut to bottom of fitting.
B. OPTIONAL PIPE FITTINGS (compression type
shown)
Note: Be sure to turn off the water supply and open
a low faucet to drain the pipe.
Complying with plumbing codes, install a fitting on
the kitchen cold water pipe to adapt 1/4" OD tubing.
A typical connection is shown in figure 3B. If
threaded fittings are used, be sure to use pipe joint
compound or Teflon tape on outside threads.
I FIG. 3 | A. WATER
"1
SUPPLY CONNECTION
J
(using included water supply fitting)
cold water
faucet stud
water supply fitting
/
lf4" green tubing to
RO inlet (see step 2, on
page 8)
cold
B. WATER SUPPLY TYPICAL CONNECTION
(using compression fitting)
- parts not included -
\
cold water
shutoff
cold
water
pipe
1/4 compression
fitting insert
1/4" tubingto _._(_ "
RO inlet (see step
2, on page 8)
5
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line