KitchenAid Instant Hot Hot Water Dispenser Water Dispenser User Manual


 
Before You Start
cont.
ruler or
measuring tape
pliers
flat-blade
screwdriver
Tools and materials needed
Parts supplied
open-end wrench(es)
to fit saddle valve
gloves
5
hand or
electric drill
bucket or pan
tubing cutter
2 mounting bracket screws (and
2 plastic anchors if attaching to
dry wall)
1/4" (6.4 mm) O.D.
copper tubing
pencil
tank
mounting
bracket
gasket
tank
clamp
Remove parts from packages.
Check that all parts were
included.
spout
assembly
1/4" (6.4 mm)
drill bit
Saddle valve kit to fit
water supply line
Kit must meet all local
codes and ordinances.
safety
glasses
For your personal safety, the hot
water dispenser must be grounded.
This appliance is equipped with a
power supply cord having a 3-prong
ground plug. To minimize possible
shock hazard, the cord must be
plugged into mating, 3-prong, ground-
type wall receptacle, grounded in
accordance with all national and local
codes and ordinances. If a mating
wall receptacle is not available, it is
the personal responsibility and
obligation of the customer to have a
properly grounded, 3-prong, wall
receptacle installed by a qualified
electrician.
Recommended ground method
Electrical requirements
Electrical Shock Hazard
Plug into a grounded 3 prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these
instructions can result in death,
fire, or electrical shock.
WARNING
If codes permit and a separate
ground wire is used, it is
recommended that a qualified
electrician determine that the
ground path is adequate.
A 120-volt, 60-Hz, AC-only 15- or
20- ampere fused, grounded
electrical supply is required. It is
recommended that a separate circuit
serving only your hot water dispenser
be provided. Use an outlet that
cannot be turned on/off by a switch.
Water supply requirements
If local codes permit, the hot water
dispenser feed line should be
connected to the cold water supply
line using a saddle tapping valve.
Important: If local codes Do Not
permit the use of saddle valves,
special feed valves can be
obtained from your local plumbing
supply distributor.
Connection to hot water line is not
recommended. Energy will be wasted
in heating the water twice and the
magnesium rod used in household
heating may produce a “rotten egg”
taste.
If this unit is replacing a hot water
dispenser connected to a hot water
supply, the existing connection may
be used.
A water filter is recommended if
your water supply contains sand,
grit or other particles. If a filter is
used, the water pressure to the
dispenser should not drop below
20 psi (138 kPa).
3-prong
ground
plug
3-prong
ground-type
wall receptacle
power
supply cord
ground
prong