KitchenAid Side-by-Side Referigerator Refrigerator User Manual


 
7
NOTE:
The set point range for the freezer is -5°F to 6°F (-21°C to
-14°C). The set point range for the refrigerator is 34°F to 46°F
(1°C to 8°C).
WATER FILTER Status & Reset
NOTE: Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction may
be used on disinfected waters that may contain filterable
cysts.
The water filter display will help you know when it is time to
change your filter. To change the filter, see the Water Filtration
System section.
After replacing the water filter, press RESET and hold for 2
seconds to change the water filter display to 99 percent.
Max Cool
The Max Cool feature assists with periods of heavy ice usage, full
grocery loads, or temporarily warm room temperatures.
Press MAX COOL to turn on the Max Cool feature. The Max
Cool indicator light will remain on for 24 hours unless
manually turned off.
NOTE:
The temperature display will remain at 34°F (1°C) and -5°F
(-21°C) for the refrigerator and freezer compartments,
respectively, while the Max Cool feature is enabled. After
24 hours, the refrigerator returns to the previous temperature set
points.
Holiday Mode
The Holiday Mode feature is designed for the traveler who wishes
to save additional energy or for those whose religious
observances require turning off the lights and ice maker. By
selecting this feature, the temperature set points remain
unchanged, the ice maker will be disabled and the interior lights
will turn off.
Press HOLIDAY MODE to turn on the Holiday Mode feature.
This feature will remain on until the Holiday Mode key is
pressed again.
NOTE:
If the Max Cool feature has been selected prior to
turning on the Holiday Mode feature, then the set points will
remain at 34°F (1°C) and -5°F (-21°C) for the refrigerator and
freezer compartments, respectively, until the Max Cool
feature times out. The refrigerator will then return to the
previous temperature set points chosen prior to the selection
of the Max Cool feature, but the lights and ice maker will
remain off until the Holiday Mode key is pressed again.
Alarm Functions
Master Alarm Reset
Pressing the OVER TEMPERATURE RESET will shut off the audio
alarm, but this does not affect the indicator light the first time the
OVER TEMPERATURE RESET is pressed. The indicator light will
shut off once the OVER TEMPERATURE RESET is pressed the
second time. The audio alarm will not sound again for the current
condition that caused the alarm until a new condition occurs or
until a Master Alarm Reset is performed.
A Master Alarm Reset can be performed by pressing the POWER
(ON/OFF) twice or by turning the power to the refrigerator off and
on again (see Power On/Off Switch section). The indicator light
will reactivate after the OVER TEMPERATURE RESET is pressed
if the condition that caused the alarm is still present (see the
Over Temperature, Call Service, or Door Open section).
Over Temperature
The Over Temperature feature is designed to let you know when
either the refrigerator temperature rises above 48°F (9°C) or the
freezer temperature rises above 15°F (-9°C) for longer than
1
¹⁄₂
hours. The audio alarm will shut off automatically when the
temperature returns to normal, but the indicator light will continue
to flash to let you know that an over temperature condition has
occurred until the OVER TEMPERATURE RESET is pressed.
If the over temperature condition is still present when an Over
Temperature Reset is performed, the indicator light will continue
to reactivate every 1
¹⁄₂
hours until refrigerator and freezer
temperatures are below 48°F (9°C) and 15°F (-9°C), respectively.
IMPORTANT:
If the Over Temperature Alarm activates, your food
may spoil. See the Power Interruptions section for more
information. Minimize door openings until temperatures return to
normal.
NOTE:
To deactivate the audio alarm and indicator light, please
see the Master Alarm Reset section.
CONDITION/REASON: TEMPERATURE
ADJUSTMENT:
REFRIGERATOR too cold
Not set correctly for conditions
REFRIGERATOR Control 1
°
higher
REFRIGERATOR too warm
High use or room very warm
REFRIGERATOR Control 1
°
lower
FREEZER too cold
Not set correctly for conditions
FREEZER Control 1
°
higher
FREEZER too warm/too little
ice
High use or heavy ice use
FREEZER Control 1
°
lower
INDICATOR: STATUS:
99 percent New filter installed
10 percent Order replacement filter
0 percent or flow decreases Replace filter