4. Use UL listed wire connectors and connect white wires (B)
together.
NOTE: The green (or green/yellow) ground wire in the conduit
from the In-line blower motor system is to be connected with the
green (or bare) wire of the home power supply cable and with the
green/yellow wire (A) in the terminal box.
5. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wires (A) in terminal box using UL
listed wire connectors.
6. Install terminal box cover.
7. Reconnect power.
Check Operation
1. Push and hold the button on the top of the downdraft vent for
a few seconds. The retractable section of the downdraft vent
will rise, and the blower will start. Position the top trim over
the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information on ordering, see the “Assistance or Service”
section.
2. Slide the control slider on the side of vent to check the
operation and speed of the blower.
3. If the blower does not operate:
Check that filter or filters are pressed in as far as they will
go.
Check that the circuit breaker has not tripped or a
household fuse blown.
4. Connect vent system to blower. Vent system must end with a
wall or roof cap. Use clamps or duct tape to seal all joints.
NOTE: To get the most efficient use from your new retractable
downdraft vent, read the “Vent System Use” section.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A.Top trim
B.On/Off button
C.Blower control slider
D.End cap
E.Filters
A
B
D
E
C