Electrical connection
The built-in cooking area must be connected to the mains supply by
a qualified electrician who is authorized to carry out such work.
Both legal wiring regulations and the requirements of your local electricity
supply board must be fully complied with.
When connecting the hob, a device must be provided which enables all-
pole disconnection of the hob from the supply with a gap construction of at
least 3 mm. Circuit breakers, fuses and contactors are considered to be
suitable disconnecting units.
When connecting and repairing the appliance disconnect it from the elec-
tricity supply with one of these devices.
Overall protection against electric shock must be ensured by the installation.
The earthed conductor lead must be sufficiently long so that, in the event
of failure of the strain relief, it is not subjected to strain until after the live
wires of the connection cable.
Any superfluous cable must be removed from the installation area beneath
the appliance.
At the factory the electronic hob has been equipped with a temperature-proof
cable with a connecting box for the oven connection cable.
The connecting box is fastened to the kitchen wall behind the built-in furniture.
If there is no built-in oven below the hob, the connecting box can also be fa-
stened to the furniture below the hob.
When assembling the connecting box remember that it must be at least
300 mm from the floor, as shown in the drawing.
The connecting box must not come into contact with any hot appliance parts.
The connecting box must not be used as a voltage distributor for other
appliances.
The appliance is connected to the mains at the connecting box as shown in
the wiring diagram. The connection may only be made in the connector box.
The connector box must not be removed.
The fitted connection cable must be replaced by the KÜPPERSBUSCH Cu-
stomer Service if it becomes damaged.
The green-yellow earth conductor must be longer than the other wires.
Connection diagram:
[
Caution: Incorrect connection results in the total destruction of the power
electronics.
[
When assembling the connecting box remember that it must be at least
300 mm from the floor, as shown in the drawing.
Electrical
connection
Permanent connection by means of an oven connection
socket.
Connection
diagram
is depicted on the underside of the appliance, suitable for
the various types of mains.
Connection data Permanent connection 400 V 3 N
~
50 Hz
(AC 230 V in UK)
Voltage of heating element: 230 V
Total connection output: 10.4 kW
400 V 3 N
~
safety current 16 A
400 V 2 N
~
safety current 20 A
230 V 1 N
~
safety current 25 A
230 V 3
~
safety current 16 A
Connection cable
Use H 05 RR-F or H 07 RN-F. Length of cable as necessary.
Cable to
the hob
base
Single-phase connection 230 V phase against neutral conductor
Supply line from
cooker junktion box
The conductor colours may be different. The connection diagram
and the terminal numbers are the decisive factors.
Three-phase connection 400 V system with 230 V phase against neu-
tral conductor
Three-phase system 230 V phase against phase