C. REMOVING CONTROL CIRCUIT BOARD (Figure 10)
(1) Remove out case.
(2) Remove door assembly.
(3) Unfasten two screws.
(4) Lift up and pull out control panel assembly carefully
from the cavity.
(5) Remove door frame.
(6) Remove the F.P.C connector from the terminal socket.
(7) Unfasten two screws which tighen the circuit board.
(8) Remove control circuit board from the door panel
assembly.
D. SEPARATE CAVITY AND BASE PLATE (Figure 11)
(1) Remove out case.
(2) Remove Door Assembly.
(3) Remove five screws at the base plate.
(Front 3 EA, Back 2 EA).
(4) Disconnect the lead wires from filter.
(5) Disconnect all the lead wires from main board.
(6) Disconnect the MGT high voltage lead wire and turn
table motor lead wire.
(7)
Lift up the cavity and disconnect the fan motor lead wire.
CAUTION: BE CAREFUL NOT TO DAMAGE LEAD
WIRE.
-15-
securing
Door frame
Unfasten screws
Unfasten screws
Disconnect the lead wires
Figure 10
Figure 11
F.P.C.Connector
Control Panel
Circuit Board
Remove screw