3 Controls and displays
3.1 Operating and control elements
Fig. 2
(1) Alarm button (8) Child-proofing symbol
(2) SuperFrost button (9) Down setting button,
refrigerator compartment
(3) On/Off button, freezer
compartment
(10)Up setting button, refriger-
ator compartment
(4) Down setting button,
freezer compartment
(11)On/Off button, refrigerator
compartment
(5) Up setting button,
freezer compartment
(12)SuperCool button
(6) Freezer compartment
temperature display
(13)Fan button*
(7) Refrigerator compart-
ment temperature
display
3.2 Temperature display
The following are displayed in normal operation:
-
the warmest freezing temperature
-
the average cooling temperature
The freezer compartment temperature display flashes:
-
the temperature setting is being changed
-
after switch-on the temperature is not yet cold enough
-
the temperature has risen several degrees
Dashes flash in the display:
-
the freezer temperature is above 0 °C.
The following displays indicate malfunction. Possible causes
and corrective action (see Malfunction).
-
nA
-
F0 to F5
4 Putting into operation
4.1 Transporting the appliance
CAUTION
Risk of injury and danger of damage as a result of incorrect
transport!
u
Transport the appliance in a packed condition.
u
Transport the appliance upright.
u
Do not transport the appliance without assistance.
4.2 Installing the appliance
In the event that the appliance is damaged, contact the supplier
immediately before connecting to the mains.
The floor at the site must be flat and level.
Do not install the appliance in a location where it is exposed to
direct radiation of the sun, next to a cooker, heater and similar.
Do not install the appliance without assistance.
Standard EN 378 specifies that the room in which you install
your appliance must have a volume of 1 m
2
per 8 g of R 600a
refrigerant used in the appliance. If the room in which the appli-
ance is installed is too small, a flammable gas-air mixture may
form in the event of a leakage in the refrigeration circuit. The
quantity of refrigerant used in your appliance is indicated on the
type plate on the inside of the appliance.
Fit the appliance in stable kitchen units only.
The following ventilation gaps must be observed:
q
The depth of the ventilation channel at the rear of the unit
must be at least 38 mm.
q
There must be a ventilation space of at least 200 cm
2
in the
plinth and at the top of the unit.
q
Basically the principle applies: the larger the ventilation
space, the more energy-saving the appliance is in operation.
WARNING
Risk of fire due to short circuit!
If the mains cable/connector of the appliance or of another
appliance touch the rear of the appliance, the mains cable/
connector may be damaged by the appliance vibrations,
leading to a short circuit.
u
Stand the appliance so that it is not touched by connectors
or main cables.
u
Do not plug the appliance or any others into sockets located
near the rear of the appliance.
WARNING
Fire hazard due to dampness!
If live parts or the mains lead become damp this may cause
short circuits.
u
The appliance is designed for use in enclosed areas. Do not
operate the appliance outdoors or in areas where it is
exposed to splash water or damp conditions.
u
Only use the appliance when it is installed.
WARNING
Fire hazard due to refrigerant!
The refrigerant R 600a is environmentally friendly but flam-
mable. Escaping refrigerant may ignite.
u
Do not damage the piping of the refrigeration circuit.
WARNING
Fire hazard and danger of damage!
u
Do not place appliances emitting heat e.g. microwaves,
toasters etc. on the appliance!
u
Detach the connecting cable from the rear of the appliance,
removing the cable holder at the same time because other-
wise there will be vibratory noise!
After installation:
u
Remove the protective film from the decorative trims and
drawer fronts.
u
Remove all transit supports.
Controls and displays