Liebherr BFI1051 Refrigerator User Manual


 
20
BFI/BF1051 / BGEN/es 2956
A delight in freshness
The following ventilation cross-section
and distances must be observed:
- There must be a ventilation space of
at least 31 square inches
(200 cm
2
) per appliance in the
cabinet plinth and under the cabinet
top panel.
- The depth of the ventilation duct at
the rear of the cabinet must be at
least 1-1/2" (38 mm).
Alternatively:
1. For built-in appliances without
ventilation grilles and only with an
installation frame, ventilation must take
place through the ventilation duct at the
rear of the cabinet.
Built-in appliances with an installation
frame:
Figure 19:
- Screw the complete installation
frame (2) to the appliance.
2. Built-in appliances with a wooden
ventilation grille:
Figure 20: Cut out the wooden trim for
use as a ventilation grille using the
enclosed template.
- The required ventilation cross-
section must be at least 31 square
inches (200 cm
2
) when a single
appliance is installed, which
corresponds to template “small” (If
you install two appliances side-
byside, the cross-section must be at
least 62 square inches, 400 cm
2
,
which corresponds to template
“double-size;” for more information
see “Side-by-Side Installation”).
Remove the attachment bracket (2)
from the installation frame and screw it
to the appliance (1) from underneath.
Place the wooden ventilation grille (5)
on the appliance, align it in the center
and secure it from the rear using the
attachment bracket (2).
Figure 19
Figure 20
2
1
5
1/2"
(13 mm)
24"
(609,6 mm)
3-11/16"
(93,7 mm)
LBR038
LBR037
1
At least 31 square inches (200cm
2
)
1
2
1 1/2”
(38mm)
2
0
3
/4
(
5
2
7
m
m
)
INSTALLATION
BGEN_7082248_0929_Install_3Lang.qxd 10/21/2004 7:56 AM Page 20