Liebherr WFI1051 Refrigerator User Manual


 
2
WF1051 / WFI 1051
A delight in freshness
INSTALLATION GUIDELINES
Area Requirements
Verify the following:
Floors can support refrigerator’s weight plus
approximately 1200 pounds (544 kg) of food
weight.
Finished kitchen floor height has to be level.
Kitchen cabinet, that the appliance is installed
in, must be shimmed to the floor level, if the
floor heights are not equal.
Remove anything attached to the rear or side
walls of appliance that would prevent proper
installation or impede proper ventillation.
Cutout dimensions are accurate.
Electrical outlet is in correct location.
Do not install this refrigerator-freezer next to any
other refrigerator or freezer except another Liebherr
model. Liebherr models are designed to allow
side-by-side installation. They are equipped with
a heating system to eliminate condensation when
refrigerators or freezers are installed side-by-side.
Installing this refrigerator-freezer next to any other
refrigerator or freezer can cause condensation or
cause damage to the Liebherr refrigerator-freezer.
Electrical Requirement
If codes require a separate grounding circuit to be
used, have a qualified electrician install the circuit.
!
WARNING
ELECTRICAL SHOCK HAZARD!
• Do not ground to a gas pipe. Check
with a qualified electrician if you
are not sure the appliance is properly
grounded. Do not have a fuse in the
neutral or grounding circuit.
Failure to follow these instructions
could result in death or serious injury.
!
WARNING
ELECTRICAL SHOCK HAZARD!
• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions
could result in fire, death or serious
injury.
!
WARNING
ELECTROCUTION HAZARD!
Electrical Grounding Required. This
appliance is equipped with a three-prong
(grounding) polarized plug for your
protection against possible shock hazards.
DO NOT remove the round grounding
prong from the plug.
DO NOT use a two-prong grounding
adapter.
DO NOT use an extension cord to
connect power to the unit.
Failure to follow these instructions could
result in death or serious injury.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp fused electrical supply
is required. We recommend using a dedicated
circuit for this appliance to prevent electrical
overload. Follow the National Electrical Code and
local codes and ordinances when installing the
receptacle.
Venting the Appliance
DO NOT restrict the air flow. Air flow must be
provided for the appliance to operate. The factory
air vents provide 31 square inches (200 cm
2
) of air
flow per appliance. If you are replacing the factory
air vents with an overlay, the air flow must be the
same or greater than the factory air vents.