Impinger X2 – Digital Service Manual – Dom & Int’l
23
6. Each conveyor motor will have a unique address on every Motor Controller PCB.
Top Belt or Top Front Belt – Dip Switch 1 will be ON, 2,3,and 4 are OFF.
Top Back Belt – Dip Switch 2 will be ON and 1, 3 and 4 are OFF.
Bottom Belt or Bottom Front Belt – Dip Switch 3 will be ON and 1,2 and 4 are OFF.
Bottom Back Belt – Dip Switch 4 will be ON and 1,2 and 3 are OFF.
CONVEYOR CONTROL – REPLACEMENT
1. Shut off power at main breaker.
2. Remove control box cover.
3. Remove wiring from appropriate conveyor control and mark all wiring for reassembly.
4. Remove conveyor control by pulling control from the mounting pins. Remove control from oven.
5. Reassemble in reverse order and set the new control for the proper operating mode. See: OVEN
CONTROL – PROGRAMMING,
6. Test system for proper operation.